Last Update: 3/24/2014


Oilfield Steam Generator (> or =20 MMBtu/hr)
Pollutant Achieved in Practice or in the SIP Technologically Feasible Alternate Basic Equipment
CO2eFEDERAL BACT =====================FEDERAL BACT ===================== Federal BACT (40CFR52.21 (b)(23)) for Sources Subject to District Rule 2410 (Prevention of Significant Deterioration) Variable frequency drive high efficiency electrical motors driving the blower; and When firing on =50% PUC quality natural gas, commercial propane, and/or LPG: a convection section with at least 235 square feet of heat transfer surface area per MMBtu/hr (HHV) of maximum rated heat input (verified by manufacturer or independent engineering/construction firm) or an overall thermal efficiency rating of 88% (verified by manufacturer or independent engineering/construction firm); or, When firing on <50% PUC quality natural gas, commercial propane, and/or LPG: split flow dual pass water feed configuration, a convection section having at least 128 square feet of heat transfer surface area per MMBtu/hr (HHV) of maximum rated heat input (verified by the manufacturer or independent engineering/construction firm) and at least six inches of castable refractory or an overall thermal efficiency rating of at least 85% (verified by manufacturer or independent engineering/construction firm); Variable frequency drive high efficiency electrical motors driving the blower; and, When firing on =50% PUC quality natural gas, commercial propane, and/or LPG: a convection section with at least 235 square feet of heat transfer surface area per MMBtu/hr (HHV) of maximum rated heat input (verified by manufacturer or independent engineering/construction firm) or an overall thermal efficiency rating of 88% (verified by manufacturer or independent engineering/construction firm); or, When firing on <50% PUC quality natural gas, commercial propane, and/or LPG: split flow dual pass water feed configuration, a convection section having at least 128 square feet of heat transfer surface area per MMBtu/hr (HHV) of maximum rated heat input (verified by the manufacturer or independent engineering/construction firm) and at least six inches of castable refractory or an overall thermal efficiency rating of at least 85% (verified by manufacturer or independent engineering/construction firm); Or other emission reduction technique determined on a case by case basis that meets the requirements of 40 CFR52.21(b)(23)FEDERAL BACT ===============
CO25 ppmvd @ 3% O2
NOx Units rated 85 MMBtu/hr and fired solely on PUC quality natural gas: 6 ppmvd @ 3% O2; or Units firing on > or = 50% PUC quality natural gas; commercial propane; and/or LPG: 7 ppmvd @ 3% O2, except units rated 85 MMBtu/hr and fired solely on PUC quality natural gas; or Units firing on <50% PUC quality natural gas; commercial propane; and/or LPG: 9 ppmvd @ 3% O25 ppmvd @ 3% O2
PM10Fired on PUC quality natural gas, commercial propane, and/or commercial LPG; or gaseous fuel treated to remove 95% by weight of sulfur compounds; or treated such that the sulfur content of all fuel streams combined does not exceed 1 gr of sulfur compounds (as S) per 100 dscf; or use of a continuously operating SO2 scrubber and either achieve 95% by weight control of sulfur compounds or achieve an emission rate of 9 ppmvd SO2 @ 3% O2
SOxFired on PUC quality natural gas, commercial propane, and/or commercial LPG; or gaseous fuel treated to remove 95% by weight of sulfur compounds; or treated such that the sulfur content of all fuel streams combined does not exceed 1 gr of sulfur compounds (as S) per 100 dscf; or use of a continuously operating SO2 scrubber and either achieve 95% by weight control of sulfur compounds or achieve an emission rate of 9 ppmvd SO2 @ 3% O2
VOCGaseous fuel


BACT is the most stringent control technique for the emissions unit and class of source. Control techniques that are not achieved in practice or contained in s a state implementation plan must be cost effective as well as feasible. Economic analysis to demonstrate cost effectiveness is requried for all determinations that are not achieved in practice or contained in an EPA approved State Implementation Plan.

This is a Summary Page for this Class of Source. For background information, see Permit Specific BACT Determinations on Details Page.