Back

Best Available Control Technology (BACT ) Guideline 1.6.27
Last Update: 8/16/2010


Direct-Fired Conveyorized Hotdog Cooking Oven
Pollutant Achieved in Practice or in the SIP Technologically Feasible Alternate Basic Equipment
NOx70.0 ppmvd @ 3% O2 (0.085 lb/MMBtu) and natural gas fuel1) 9.0 ppmvd @ 3% O2 using ultra-low NOx burner system, or equivalent control technology 2) 20.0 ppmvd @ 3% O2 using ultra-low or low-NOx burner system, or equivalent control technology
PM10At least 95% overall control (properly designed capture system vented to regenerative thermal oxidizer or equal)
VOCAt least 98% overall control (properly designed capture system vented to regenerative thermal oxidizer or equal)


BACT is the most stringent control technique for the emissions unit and class of source. Control techniques that are not achieved in practice or contained in s a state implementation plan must be cost effective as well as feasible. Economic analysis to demonstrate cost effectiveness is requried for all determinations that are not achieved in practice or contained in an EPA approved State Implementation Plan.

This is a Summary Page for this Class of Source. For background information, see Permit Specific BACT Determinations on Details Page.