Back

Best Available Control Technology (BACT ) Guideline 4.3.12
Last Update: 8/2/1995


Metal Products Coating - High Gloss, Air-Dried,= or < 30 lb/day Facility-wide VOC coating emissions
Pollutant Achieved in Practice or in the SIP Technologically Feasible Alternate Basic Equipment
PM10Spray booth with exhaust filtersElectrostatic application
VOCHVLP spray guns, coatings compliant with District rules and enclosed paint gun cleanersVOC capture and control systemElectrostatic application


BACT is the most stringent control technique for the emissions unit and class of source. Control techniques that are not achieved in practice or contained in s a state implementation plan must be cost effective as well as feasible. Economic analysis to demonstrate cost effectiveness is requried for all determinations that are not achieved in practice or contained in an EPA approved State Implementation Plan.

This is a Summary Page for this Class of Source. For background information, see Permit Specific BACT Determinations on Details Page.