Best Available Control Technology (BACT ) Guideline 4.3.18
Last Update: 10/4/2011


Metal Product Coating - Metal Rod Dip Coating, Air-Dried
Pollutant Achieved in Practice or in the SIP Technologically Feasible Alternate Basic Equipment
VOCDip coating with materials in compliance with Rule 4603 and leak-free dip tank covered when not in use1. VOC capture and incineration or carbon adsorption with overall capture/destruction efficiency of > or = 90% and use of materials in compliance with Rule 4603 and leak-free dip tank covered when not in use


BACT is the most stringent control technique for the emissions unit and class of source. Control techniques that are not achieved in practice or contained in s a state implementation plan must be cost effective as well as feasible. Economic analysis to demonstrate cost effectiveness is requried for all determinations that are not achieved in practice or contained in an EPA approved State Implementation Plan.

This is a Summary Page for this Class of Source. For background information, see Permit Specific BACT Determinations on Details Page.