Back

Best Available Control Technology (BACT ) Guideline 4.8.19
Last Update: 10/8/2001


Fiberglass-reinforced Composite Products Pultruded, heat set resin products.
Pollutant Achieved in Practice or in the SIP Technologically Feasible Alternate Basic Equipment
VOCUse of polyester resins with 35% monomer by weight, or less, and Use of epoxy-based resins with 1% VOC by weight, or less, and Use of a covered, resin-product cooling bath.1. Thermal/catalytic incineration. 2. Carbon adsorption system.


BACT is the most stringent control technique for the emissions unit and class of source. Control techniques that are not achieved in practice or contained in s a state implementation plan must be cost effective as well as feasible. Economic analysis to demonstrate cost effectiveness is requried for all determinations that are not achieved in practice or contained in an EPA approved State Implementation Plan.

This is a Summary Page for this Class of Source. For background information, see Permit Specific BACT Determinations on Details Page.